CONFIGURING THE METER

USING SETPOINT 1 CONFIGURATION ("S1.CF")

Note: Refer to Table 6-1 for a summary list of menu configuration.

Setpoint 1 Configuration (S1.CF) is not active unless your meter has dual relay output capabilities. The LED's will display whether the ("S1.CF") is active or not. You may use Setpoint 1 Configuration ("S1.CF") for the following:
    * To Set setpoint's active band above or below your chosen value
    * To Select whether the setpoint operation is latched or unlatched
Setting Setpoint 1's Active Band
1. Press the MENU button until the meter shows "S1.CF".

2. Press the /TARE button. The meter shows one of the following:
* "S.1=A" (Active above the deadband) (default)
* "S.1=B" (Active below the deadband)

3. Press the /MAX button to toggle between available choices.

4. Press the /TARE button to select if Setpoint 1 is latched or unlatched or press the MENU button to store your selection.

Selecting if Setpoint 1 is Latched or Unlatched
1. Press the "MENU" button until "S1.CF" displays, then press the /TARE button twice.
or Press the /TARE button from "S.1".
The meter shows one of the following:

* "S.2=U" (setpoint 1 to be unlatched) (default)
* "S.2=L" (setpoint 1 to be latched)

2.
Press the /MAX button to toggle between available choices.

3. Press the MENU button to store your selection(s). The meter momentarily shows "STRD", followed by "S2.CF" (Setpoint 2 Configuration).

USING SETPOINT 2 CONFIGURATION ("S2.CF")

Note: Refer to Table 6-1 for a summary list of menu configuration.

Setpoint 2 Configuration ("S2.CF") is not active unless your meter has dual relay output capabilities. The LED's will display whether the ("S2.CF") is active or not. You may use Setpoint 2 Configuration ("S2.CF") for the following:
    * To set setpoint's active band above or below your chosen value
    * To select whether the setpoint operation is latched or unlatched
Setting Setpoint 2's Active Band
1. Press the MENU button until the meter shows "S2.CF".


2. Press the /TARE button. The meter shows one of the following:
* "S.1=A" (Active above the setpoint) (default)
* "S.1=B" (Active below the setpoint)

3. Press the /MAX button to toggle between available choices.

4. Press the /TARE button to select if Setpoint 1 is latched or unlatched or press the MENU button to store your selection and enter "S1.DB" (Setpoint 1 Deadband)

Selecting if Setpoint 2 is Latched or Unlatched
1. Press the "MENU" button until "S2.CF" displays, then press the /TARE button twice.
or Press the /TARE button from "S.1".

The meter shows one of the following:
* "S.2=U" (setpoint 1 to be unlatched) (default)
* "S.2=L" (setpoint 1 to be latched)

2. Press the /MAX button to toggle between available choices.

3. Press the MENU button to store your selection(s). The meter momentarily shows "STRD", followed by "S1.DB" (Setpoint 1 Deadband).

SETTING THE SETPOINT 1 DEADBAND ("S1.DB")

Note:
Refer to Table 6-1 for a summary list of menu configuration.

Setpoint 1 Deadband ("S1.DB") is not active unless your meter has dual relay output capabilities. The LED's will display whether the ("S1.DB") is active or not. The Setpoint 1 default deadband is 0003. To change the deadband (hysteresis) of setpoint 1, follow these steps:

1. Press the MENU button until the meter shows "S1.DB".

2. Press the /TARE button. The meter shows the last previously stored 4-digit number (0000 through 9999) with flashing 4th digit.

3. Press the /MAX button to change the value of the flashing digit. If you continue to press the /MAX button, the flashing digit's value continues to change.

4. Press the /TARE button to scroll to the next digit.

5. Press the MENU button to store your selection. The meter momentarily shows "STRD", followed by "S2.DB" (Setpoint 2 Deadband).


SETTING THE SETPOINT 2 DEADBAND ("S2.DB")

Note: Refer to Table 6-1 for a summary list of menu configuration.

Setpoint 2 Deadband ("S2.DB") is not active unless your meter has dual relay output capabilities. The LED's will display whether the (S2.DB) is active or not. The Setpoint 2 default deadband is 0003. To change the deadband (hysteresis) of setpoint 2, follow these steps:

1. Press the MENU button until the meter shows "S2.DB".

2. Press the /TARE button. The meter shows the last previously stored 4-digit number (0000 through 9999) with flashing 4th digit.

3. Press the /MAX button to change the value of the flashing digit. If you continue to press the /MAX button, the flashing digit's value continues to change.

4.
Press the /TARE button to scroll horizontally to the next digit.

5. Press the MENU button to store your selection. The meter momentarily shows "STRD", followed by "OT.CF" (Output Configuration) if you have analog output capabilities.


Alarm Example Figure 4-1

To reset latched alarms you must:
1. Input a signal "OUT" of the alarm zone
2. Then press SETPTS and then, RESET button